Samsung SSD Wear-Leveling-Count" Bedeutung

Ich habe Samsung SSDs auf meinem eigenen Laptop und auf einigen Servern.

Wenn ich:

smartctl -a /dev/sda | grep 177

Ich erhalte Ergebnisse, die ich nicht verstehen kann. Hier einige Beispiele:

# my laptop Samsung SSD 850 EVO 500GB (new)
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
177 Wear_Leveling_Count     0x0013   100   100   000    Pre-fail  Always       -       0

# server 256 GB, SAMSUNG MZ7TE256HMHP-00000
177 Wear_Leveling_Count     0x0013   095   095   000    Pre-fail  Always       -       95

# server 512 GB, SAMSUNG MZ7TE512HMHP-00000 (1 year old)
177 Wear_Leveling_Count     0x0013   099   099   000    Pre-fail  Always       -       99

# server 512 GB, SAMSUNG MZ7TE512HMHP-00000 (suppose to be new)
177 Wear_Leveling_Count     0x0013   099   099   000    Pre-fail  Always       -       99

# server 480 GB, SAMSUNG MZ7KM480HAHP-0E005
177 Wear_Leveling_Count     0x0013   099   099   005    Pre-fail  Always       -       3

# server 240 GB, SAMSUNG MZ7KM240HAGR-0E005
177 Wear_Leveling_Count     0x0013   099   099   005    Pre-fail  Always       -       11

Irgendeine Idee, wie man Wear_Leveling_Count liest?

Einige Werte sind minimal, andere maximal.

Wenn man "laptop" Samsung SSD 850 EVO 500GB betrachtet, ist es 0 und wird wahrscheinlich zu 100 gehen, dann wird fehlschlagen.

Wenn der erste "Server" 256 GB, SAMSUNG MZ7TE256HMHP-00000, ist es bereits am Maximum? Wird es auf Null gehen?

 39
Author: Chenmunka, 2016-02-09

3 answers

Bitte beschreiben Sie dieses INTELLIGENTE Attribut wie folgt:

Anzahl der Lösch - / Programmzyklen pro Block im Durchschnitt. Dieses Attribut ist soll ein Indikator für den bevorstehenden Verschleiß sein. Normalisierte Gleichung: 100 - ( 100 * Durchschnitt Löschen Anzahl / NAND max bewertet anzahl von löschen Zyklen)

Ignorieren Sie die Raw Data in diesen Fällen (sie können von Herstellern manipuliert werden, um auf verschiedene Arten zu arbeiten), und schauen Sie sich die Current Value spalte.

Diese Quelle aus Anandtech gibt uns einen guten Hinweis auf die Verwendung dieser Figur:

Die Wear-Leveling-Count (WLC) SMART-Wert gibt uns alle Daten, die wir brauchen. Der aktuelle Wert steht für die verbleibende Dauer der fahren Sie in Prozent, was bedeutet, dass es von 100 beginnt und abnimmt linear wie das Laufwerk geschrieben wird. Der rohe WLC-Wert zählt die verbrauchte P/E-Zyklen, also wenn diese beiden Werte überwacht werden, während schreiben auf das Laufwerk, früher als später werden wir die Stelle finden wo der normalisierte Wert sinkt um eins.

Alle Ihre Laufwerke liegen zwischen 95 und 100 und fallen schließlich auf 0. Dies ist eine Schätzung, wie viele write, erase, rewrite etc. Zyklen pro block Durchlaufen können, bevor der Vorgang abgebrochen, und in dem Augenblick, einem der Laufwerke ist geschätzt verwendet wurden 5% der erwarteten Lebensdauer. Auch hier wird das Schlüsselwort hier geschätzt.

Beachten Sie auch, dass Ihre Laufwerke unterschiedliche NAND-Technologie verwenden können, daher die unterschiede im wahrgenommenen Leben. Einige NAND-Technologie erwartet Blöcke für rund 1000 PE-Zyklen jeweils dauern, andere können für so viel wie 30.000 bewertet werden.

 53
Author: Jonno,
Warning: date(): Invalid date.timezone value 'Europe/Kyiv', we selected the timezone 'UTC' for now. in /var/www/agent_stack/data/www/techietown.info/template/agent.layouts/content.php on line 61
2016-02-09 16:31:23

SMART meldet eine VORGEFERTIGTE Bedingung für mein Samsung SM951 (AHCI) 128GB, die unter Linux als SAMSUNG MZHPV128HDGM-00000 (BXW2500Q) gemeldet wurde.

Aber in meinem Fall denke ich, es ist ein Firmware-Fehler des Laufwerks,

  • weil die Eigenschaft total-bytes-written als 1.1 TB gemeldet wird, während auf dem Laufwerk eine angegebene Gesamtbyteanzahl (TBW) von 75 TB angegeben ist! Was wahrscheinlich auf der (sehr) Rettungsseite liegt, denn ähnliche (MLC NAND) Laufwerke erreichten alle eine Vielzahl davon (600TB) in einem echten Dauertest,
  • und abgesehen von der wear_level_count warnung es werden keine anderen Prefail-oder Oldage-Fehler oder Warnungen gemeldet,
  • während die reallocated-sector-count, die nach diesem Test ist gut Pre-Fail-Indikator, ist immer noch 0.

Mein Rat wäre also, diese Werte für Ihr Laufwerk/System zu untersuchen und Ihre Schlussfolgerungen darauf zu stützen.

Bevorzuge ich die low-level-Hilfsprogramm - skdump, geliefert mit libatasmart, derselben Bibliothek, die von Gnome-Disks.

Verwenden Sie den folgenden Befehl und ersetzen Sie /dev/sdc durch den Pfad zu Ihrem Blockgerät:

sudo skdump /dev/sdc

 3
Author: Ronald,
Warning: date(): Invalid date.timezone value 'Europe/Kyiv', we selected the timezone 'UTC' for now. in /var/www/agent_stack/data/www/techietown.info/template/agent.layouts/content.php on line 61
2018-10-19 13:14:15

Kurze Notiz auf Samsung EVO und PRO SSD:

smartctl -a /dev/sda

smartctl 6.4 2014-10-07 r4002 [x86_64-linux-4.9.0-0.bpo.6-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     Samsung SSD 860 PRO 1TB
Serial Number:    S42NNF0K000000
LU WWN Device Id: 5 002538 e405145c6
Firmware Version: RVM01B6Q
User Capacity:    1,024,209,543,168 bytes [1.02 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   Unknown(0x09fc) (unknown minor revision code: 0x005e)
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Fri Jan  8 11:53:56 2021 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                    was never started.
                    Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                    without error or no self-test has ever 
                    been run.
Total time to complete Offline 
data collection:        (    0) seconds.
Offline data collection
capabilities:            (0x53) SMART execute Offline immediate.
                    Auto Offline data collection on/off support.
                    Suspend Offline collection upon new
                    command.
                    No Offline surface scan supported.
                    Self-test supported.
                    No Conveyance Self-test supported.
                    Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                    General Purpose Logging supported.
Short self-test routine 
recommended polling time:    (   2) minutes.
Extended self-test routine
recommended polling time:    (  85) minutes.
SCT capabilities:          (0x003d) SCT Status supported.
                    SCT Error Recovery Control supported.
                    SCT Feature Control supported.
                    SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0032   097   097   000    Old_age   Always       -       14689
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       122
177 Wear_Leveling_Count     0x0013   098   098   000    Pre-fail  Always       -       25
179 Used_Rsvd_Blk_Cnt_Tot   0x0013   100   100   010    Pre-fail  Always       -       0
181 Program_Fail_Cnt_Total  0x0032   100   100   010    Old_age   Always       -       0
182 Erase_Fail_Count_Total  0x0032   100   100   010    Old_age   Always       -       0
183 Runtime_Bad_Block       0x0013   100   100   010    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0032   067   056   000    Old_age   Always       -       33
195 Hardware_ECC_Recovered  0x001a   200   200   000    Old_age   Always       -       0
199 UDMA_CRC_Error_Count    0x003e   099   099   000    Old_age   Always       -       23
235 Unknown_Attribute       0x0012   099   099   000    Old_age   Always       -       58
241 Total_LBAs_Written      0x0032   099   099   000    Old_age   Always       -       29068641040

Der interessanteste Teil dieses Indikators ist also:

ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
177 Wear_Leveling_Count     0x0013   098   098   000    Pre-fail  Always       -       25

25 für Rohwert??? Bedeutet das, ich habe 25 Prozent der Lebenszeit erschöpft?

, Wirklich nicht. Bitte sehen Sie, was Samsung schrieb:

SMART-Attribut 177 (Wear Leveling Count)

Dieses Attribut repräsentiert die Anzahl der Medienprogramm - und Löschvorgänge (die Anzahl der Löschvorgänge eines Blocks). Dieser Wert steht in direktem Zusammenhang mit der Lebensdauer des SSD. Der Rohwert dieses Attributs zeigt die Gesamtzahl der P / E-Zyklen an.

Dies bedeutet, dass in meinem speziellen SSD-WERT 98 immer noch 98 Prozent der Lebensdauer angezeigt werden, aber die durchschnittlichen Programm - /Löschzyklen pro Block sind 25-mal.

Eine weitere interessante Sache:

241 Total_LBAs_Written      0x0032   099   099   000    Old_age   Always       -       29068641040

Was ist diese Größe in GB? TB?

Sehr einfach. Nehmen Sie INTELLIGENTE Informationen, um die Sektorgröße zu erhalten:

Sector Size:      **512** bytes logical/physical

Insgesamt Gigabyte oder Terabyte geschrieben:

29068641040/2/1024/1024/1024 = 13847 GB / 1024 = 13.52 TB

Erklärung: Teilen Sie die LBA-Anzahl durch 2, da 1 KB aus 2 512B-Sektoren besteht. Teilen Sie dann durch 1024, um KB, MB, GB und TB zu erhalten.

Hoffe es hilft.

 1
Author: Arunas Bartisius,
Warning: date(): Invalid date.timezone value 'Europe/Kyiv', we selected the timezone 'UTC' for now. in /var/www/agent_stack/data/www/techietown.info/template/agent.layouts/content.php on line 61